It is a good way to enhance our products and solutions and repair. Our mission will be to build creative solutions to consumers with a great experience for Holter Monitor Leads , Electrical Leads , Electronic Surgery , We hope we are able to have a pleasant partnership with businessman from all over the environment.
China Manufacturer for Ems Electrode Pad - 3M Pre-Wire Disposable Neutral Electrode – Quanding Detail:
Product Specification
For Adult |
For Child |
Infant |
QD202B-A |
QD202B-P |
QD202B-1 |
Bipolar /Split |
Monopolar/single |
Bipolar/Monopolar |
102*202mm |
90*148mm |
53.5*124mm |
Packaging |
1pc/foil bag
350pcs/carton |
|
Carton Size |
45*45*28CM
GW: 15.4kg |
|
Certification |
ISO13485,CE |
|
Storage
|
The product must be stored in its original package at the environmental conditions (temperature and relative humidity) specified on the pouch’s label. Putting external heavy weights on the package could damage the product. |
Product Instructions.
1. Select a well convex area (muscle) next to the area to be operated but at least 20 cm far from it, possibly on the forearm, on the thigh or on a whip. Eventually move the plate in order that the longer side is perpendicular to the area of the operation (see the picture). Avoid that the plate is superimposed.
2.NB Current should flow in parallel to the body surface and never pass through the thorax. The patient must be placed on a dry and perfectly isolated surface. The patient must be kept isolated from conductive parts and the operating bed must be earthed. Use dry gauzes to avoid that different areas of the body come into contact with each other.
3. Do not place the plate on wounds and scars, near bone projections, very adipose tissues, close to metallic prosthesis or to ECG electrodes
or on areas, where liquids can flow.
4.Do not place the plate on areas, where it can be subjected to pressure or under patient’s weight.
5.Shave the selected area, clean carefully and skim in order to remove eventual remaining of cream or cosmetics. Dry the selected area.
6.NB Do not use inflammables during the patient’s preparation. Do not use alcoholic substances or benzoine tincture.
7.Eventual shave remaining or hair can cause burns.
Application
- After controlling the packing for damages, check the plates and gel. Do not use the product in the case of damages or visible defects. Instead, return it to FIAB.
- Only open package immediately before use.
- Take off the protection film and place the plate on the prepared area; place it starting from a side and continue with same pressing until the opposite side.
- Make sure that the entire surface of the plate is in contact with the patient’s skin.
- Avoid excessive contact between fingers and adhesive. Do not touch the gel . NB There must not be air bubbles or parts of the adhesive support not perfectly close to the patient.
- Connect the plate to the high-frequency generator using the connectorcable . For neutral plate without connection cable: lift the connector lever and plug in the tongue.Make sure to plug in the tongue until the end, then close the lever. Then connect the generator to the pencil and the eventual foot control.
Warning
1. This is a disposable product – do not re-use.
2. The product is supplied not sterile – do not sterilize.
3. Do not re-position or cut the plate, do not add gel.
4. Do not use the product in case:
5. The packaging is not complete
6.There are evident damages on the plate or on the connection cable, Gel is not homogeneous or is dry.
7.Do not submit a patient with implanted pacemaker to electrosurgical current without first consulting a cardiologist.
8. The devices are to be used by trained healthcare professionals in electrosurgical procedures.
9. Do not use paediatric plates for high-power procedures (such as trans-urethral resection – TUR).
Product detail pictures:
Related Product Guide:
Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of employees building, striving hard to boost the standard and liability consciousness of staff members. Our corporation successfully attained IS9001 Certification and European CE Certification of China Manufacturer for Ems Electrode Pad - 3M Pre-Wire Disposable Neutral Electrode – Quanding , The product will supply to all over the world, such as: UK, Korea, South Africa, Make sure you genuinely feel free to send us your requirements and we are going to respond for you asap. We now have got a skilled engineering group to serve for your just about every detailed needs. Cost-free samples could be sent to suit your needs personally to understand much more information. In an effort to meet your requires, be sure to seriously feel free to make contact with us. You may send us emails and contact us directly. Moreover, we welcome visits to our factory from around the globe for much better recognizing of our organization. nd objects. In our trade with merchants of numerous countries, we usually adhere for the principle of equality and mutual benefit. It is really our hope to market, by joint efforts, each trade and friendship to our mutual advantage. We look forward to getting your inquiries.