medical product

Products

Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Now we have superior devices. Our solutions are exported to your USA, the UK and so on, enjoying a superb name between customers for Tens Machine For Labour , Grounding Cable , Best Ems Machine , Welcome all nice buyers communicate details of solutions and ideas with us!!
Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding Detail:

Product Specification

Model

QD-H1 Handswitching pencil with button switch Sterile QD-H2 Handswitching pencil with rocker switch Steril
Disposable yes
Pencil color Blue
Control type Hand control ,button swith
Electrode type 70mm stainless steel tip
Cable length 3m PVC-medical cable
Maximaloutput current 1A
Frequency confine 0-1MHZ
Package Single package,1pc/paper bag 100pcs/carton,46*23*27CM GW:8KG  NW:7KG
Sterile EO
Certification ISO13485,CE,FDA510K

Product Advantage

Standard feature that compatible with most standard electrodes and electrosurgical unit
Anti-slip design for comfortable grip and operation in surgeon’s hand
Latex free
Max electrical capacity 8kv
Handswitching pencils are available with either push-button or rocker switch controls to accommodate the surgeon’s preference.
Switches have a high level of tactile feedback – surgeons can hear and feel the switch engage, preventing accidental activation of
the device.

Designed with the surgeon in mind
• Slim and lightweight, tapered ergonomic design, streamlined design,
• Slip-proof handling and water resistant Rocker or Push-Button Switch
• Switch and buttons designed for smooth activation
• Equip with a range of monopolar cutting and coagulation electrodes to satisfy all users requirements.
• With hexagonal shape to protect against inadvertent twisting, the electrodes can be locked safely into place and are easily
exchanged and replaced.

• Contraindications of electrosurgical pencil
Electrosurgical pencil is widely used in clinical practice. It uses the high-frequency and high-voltage current generated by the effective electrode tip to heat, cut and stop bleeding when contacting body tissues, so as to achieve the separation and solidification of body tissues. It has the advantages of thorough hemostasis, convenient operation and shortened operation time. The contraindications mainly include patients with pacemaker installed, contact with combustible materials, and other contraindications.

> Patients with cardiac pacemaker installation: high-frequency electrosurgical pencil can not be used in general, because the electrosurgical pencil current will interfere with the operation of cardiac pacemaker, making it work abnormally or even stop;

>  Contact with combustible materials: Electric arc will be formed when the surgical electric knife is used, and flammable materials will burn or explode when encountered. Therefore, flammable materials should be avoided in the surgical area. Mannitol enemas are forbidden in intestinal surgery to avoid explosions. When using iodine and alcohol to disinfect the surgical area, towels and surgical film can be spread before alcohol is completely dry and volatile, and alcohol cotton balls should be removed from the operating table in time.

> Other precautions: Repeat use of disposable negative plate is prohibited, and cross-infection and burns should be prevented. At the same time, the smoke and particles produced by the electric knife are harmful to human body, so they should be removed in time. In addition, can not blindly increase the output power, to prevent increased body tissue damage. After use, the eschar on the electric knife head should be removed in time to keep the electric knife clean and dry. Avoid washing the electric knife with bubbles directly, or it may be damaged easily.


Product detail pictures:

Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding detail pictures

Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding detail pictures

Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding detail pictures

Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding detail pictures

Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding detail pictures


Related Product Guide:

We have the most advanced production equipment, experienced and qualified engineers and workers, recognized quality control systems and a friendly professional sales team pre/after-sales support for Factory directly supply Graphite Electrode Manufacturer - EOS Disposable Electrosurgical Diathermy Pencil with Blade Electrode – Quanding , The product will supply to all over the world, such as: Montreal, Ghana, Morocco, By adhering to the principle of "human oriented, winning by quality", our company sincerely welcomes merchants from at home and abroad to visit us, talk business with us and jointly create a brilliant future.
  • We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Carey from Angola - 2018.06.30 17:29
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Linda from Doha - 2018.09.16 11:31